mirror of
https://github.com/screentinker/screentinker.git
synced 2026-08-14 14:23:14 -06:00
2 commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
4e1de8ec0e |
Make the Tizen and BrightSign players do what they say they do
Both players carried calls that compile, read correctly, and are documented to
do something else. Verified line by line against docs.brightsign.biz and
Samsung's Smart TV Filesystem reference; every fix below cites the doc that
proves it, and the linter has been extended so each one fails here next time.
TIZEN
The offline media cache could never have worked on a panel. Its adapter used
the deprecated Filesystem API in three ways the IDL rules out:
`tizen.filesystem.resolve()` is declared `void`, so `var dir = resolve(...)`
was always undefined and MediaCache.create() returned null on every panel in
the fleet; `openStream()` is asynchronous, so appendPart read `written` before
any callback could run and returned 0 forever; and `moveTo()` is asynchronous,
belongs on the parent directory, and takes (origin, destination) — it was
called on a file handle with the arguments transposed. Rewritten against the
5.0 synchronous FileSystemManager, which is genuinely synchronous and is what
the decision layer needs. A Tizen 4.0 panel now reports available() false
instead of being handed a cache that silently writes nothing.
Writes are now POSITIONED rather than appended at EOF. Power cut between a
write and the index save — the exact event this feature exists for — replayed
the last chunk, and an append landed it twice: a silently corrupt video that
promoted as complete. A positioned write makes the replay idempotent.
Three decision-layer bugs alongside it: a 206 with no readable Content-Range
fell back to Content-Length, which is the CHUNK length, so the first megabyte
of a 50MB video promoted as a complete 1MB asset; a 200 whose body was short of
its own Content-Length returned 'done'; and a server with no ETag or
Last-Modified was re-fetched from zero on every sweep, forever, on precisely
the marginal link this feature exists to be gentle on.
The volume slider was dead. The dashboard sends `{level: 0..1}`; this handler
read `value`/`volume` as a 0..100 percentage, so it matched nothing and logged
"no usable value in payload" on every slider move while the panel declared
audio.volume as working. Both halves had to move together — taking `level` as a
percentage turns 50% into 0.5%, which is inaudible and looks like a fix.
Verified by driving the real handler in headless Chrome, before and after.
BRIGHTSIGN
FindMemberFunction is documented as available only when
roDeviceInfo.HasFeature("FindMemberFunction") is true. It was called
unguarded from the capability probe and from host telemetry — both on the event
loop — so a player without the feature would have died within a minute of boot
and taken the display with it. The guard needed guarding.
The boot report never arrived. The host flushed its buffer straight after
Show(), before the page had been fetched, while the player correctly waits for
its socket before subscribing. Between two correct decisions every boot line
fell on the floor. The host now waits for the page's `probe`, and the bridge
buffers until a consumer registers.
offline.cache was claimed on `navigator.serviceWorker` being present. It is
present on a BrightSign widget and will not run a worker — our XT245 passes the
check and never fetches sw.js. Now requires a controller, matching the web
player. Removed from the brightsign baseline for the same reason.
display.resolution was claimed on @brightsign/videooutput, which has no
setMode at all; mode setting lives on @brightsign/videomodeconfiguration.
roStorageHotplug.GetStorages() answers "USB1:/" while GetStorageStatus() is
documented as unreliable for "USBn:" — feeding one to the other re-created the
bug the static fallback list exists to avoid, and only on the OS versions that
have the enumerator.
dual/clone output mode put two full-screen widgets on output ONE, on top of
each other, while output two stayed dark: roHtmlWidget has no output selector,
and a second output is addressed by its display_x/display_y within the
SetScreenModes canvas. Now positioned properly, or refused with a reason.
Also: a manifest missing sha256/size passed `invalid` into typed parameters, a
runtime error at the call the comment already described and did not prevent;
storage_quota was a string where the docs say use a double; and the comment
crediting brightsign_js_objects_enabled with gating require("@brightsign/*")
named the wrong flag — it is nodejs_enabled.
TESTS
The two suites that mattered most were the ones that passed while the code was
broken, because they asserted on source text or against a fake more correct
than the platform. The host-diagnostics regexes now execute the bridge; the
media-cache suite now drives the shipped adapter against a fake tizen.filesystem
written from Samsung's IDL. Ten new rules in the BrightScript linter, each
verified to fail against the source it was written to reject.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Uaeo9MvzKoyXuN6ZsbhtkL
|
||
|
|
5fe55307ba |
brightsign: declare capabilities from real hardware state
The dashboard offered every control to every display. This makes the
BrightSign player answer for itself, at runtime, rather than from a
per-platform table.
The table cannot work here: the same XT245 supports remote screenshots
with an SSD fitted and not without, because the DWS snapshot endpoint
writes the full-size capture to disk before returning a thumbnail and
answers "No primary storage found" on a flash-booted unit. So the bridge
asks the host.
- autorun.brs gains StorageProbe()/SendProbeResult(): walks SSD:, SD:,
USB1: via roStorageHotplug.GetStorageStatus().mounted and reads real
capacity through roStorageInfo. FLASH: is excluded deliberately — it is
where the player boots from, not a volume the DWS accepts. Neither API
has a JS equivalent, which is why this has to cross the bridge.
- st-bridge.js posts the probe during boot and folds the answer into the
existing readiness gate, with its own 3s timeout so a widget built
without nodejs_enabled still becomes ready. computeCapabilities() then
gates remote.screenshot/remote.stream/system.self_update on a mounted
volume, the lifecycle and display commands on a live host, sync.native
on the module AND OS >= 8.2.10, and display.power on CEC module
presence.
Unknown is treated as NO throughout: an unanswered probe declares
nothing storage-gated. A control that appears once a disk is fitted is
a smaller problem than one that silently fails.
Never declared: kiosk, brightness, screen_timeout, install_apk, shell
(no BrightSign equivalent) and time (BrightScript can, this host does
not implement it — the same lie in the other direction).
- Telemetry now reports the real drive from the probe instead of the
widget's storage_quota, which it had been presenting as if it were the
disk.
Two declarations are knowingly optimistic and documented as such:
transitions/pip composite DOM over a hardware plane and may be invisible
over video (the roVideoMode.SetGraphicsZOrder("front") fix wants a
hardware experiment, not a guess), and display.power rides module
presence on a unit whose kernel logs "failed to get cec clock". Neither
is load-bearing — transitions degrade to a hard cut, blanking works by
tearing the media down.
Tests cover the storage split, the hostless case, the sync floor, the
never-declared set, and that every declared string is in the server's
vocabulary — a typo there would silently disable a control fleet-wide.
|