#148 / #147 — "mass simultaneous disconnect" analysis (investigate-first)

Status: analysis only. No code changed, nothing deployed.

Headline (the FIX-or-CARRY verdict Dan needs)

v1.9.2 does NOT fix #148/#147, and telling Bold to upgrade to it as "the fix" is not supported by the evidence — it may make the visible symptom worse.

  • The disconnect is client-initiated and MAXHUB-specific, per #148's own server logs and the clean same-server comparison (a Fire TV Stick on the same server, same APK, same network stays connected; the MAXHUB drops). The server does not initiate it.
  • The bug reproduces on every APK in the fleet (1.9.0 → 1.9.2), and 1.9.2's Android player socket code is byte-identical to beta5 — the only android change between them is the versionCode bump in build.gradle.kts. So the 1.9.2 APK will behave identically.
  • Worse: 1.9.2 ADDS a flap-limiter with a 30-minute in-memory quarantine that beta5 does not have. A MAXHUB that flaps (which is exactly what #148 describes) will be throttled and then quarantined more aggressively on 1.9.2 than on beta5 — i.e. it may "go offline and stop retrying" faster.
  • The one genuine server-side fix in 1.9.2 (the event-loop-freeze death spiral) is real but addresses a different failure mode that is not present in #148 (there is no freeze, no restart, no server-initiated close in the #148 logs).

Recommendation: walk back the "upgrade to 1.9.2 fixes this" advice. The fix must target the MAXHUB Android client's WebSocket lifecycle, not the server.


Phase 0 — the evidence (and the contradiction in the framing)

There are two competing narratives, and the primary evidence resolves them:

#148 body + server logs (empirical):

  • "Fire TV Stick on the same APK, same network, same server stays connected indefinitely — this is MAXHUB-specific."
  • "Every disconnect is client-initiated — server sees a clean disconnect with the 5000ms offline-transition deferral, then nothing."
  • "No errors, no blocks, no quarantine, no throttle except after rapid reconnect cycling (throttle correctly identified the flapping)."
  • Trigger point: after the initial content load completes ("connect, register/pair, receive content, then drop"), then loops connecting/waiting, then stops retrying.

Bold's later comment (the inference the task framing is built on):

  • "mass simultaneous disconnect across separate physical locations proving the trigger is server-side."

These contradict, and the primary evidence wins: a server-side mass event would be server-initiated (the logs say client-initiated) and would drop the Fire TV too (it doesn't). So "server-side" is not supported.

Disconnect timing / periodicity

There is no fixed interval or wall-clock trigger in #148. The trigger is a per-device lifecycle event — completion of the initial content load. The appearance of periodicity / simultaneity is a reporting artifact (see below), not a server clock.

Server-initiated vs missed-heartbeat — missed-heartbeat, client-initiated

The server never closes these sockets. Per the logs it observes the client close (clean transport disconnect), starts the 5s offline-transition deferral (the #146 reconnect containment), then marks the device offline because no heartbeat/registration follows.


Phase 1 — proof there is NO server-side mass-disconnect (1.9.2 / current main)

Audited every path that can drop a device socket:

Mechanism Can it close sockets? Can it fire fleet-wide at once?
Heartbeat checker (services/heartbeat.js) No — it UPDATE devices SET status='offline' in the DB (line 29) and deletes the in-memory conn; it never calls disconnect(). Line 45 is a safety continue-if-the-socket-is-still-live. Marks offline in the DB in a batch each 10s tick, but does not disconnect anything.
Flap limiter / reconnect throttle Yes — refuses a register and disconnect(true)s that one socket Only per-identity: a device is refused only if it exceeds 20 connects/5min. Not global.
Operator block Yes — one socket, only a blocked=1 device No
Evict-prior-socket Yes — the device's own previous socket on reconnect No
protectSocket (safe-socket.js) Yes — the one socket whose handler threw No
Maintenance / prune No — chunked, yields; touches tables, not sockets No
Global teardown (io.disconnectSockets(), namespace close, timer) Does not exist

There is no code path that disconnects many device sockets simultaneously. The only "batch, periodic" behavior is the heartbeat checker marking devices offline in the DB — which is the server reporting that clients are gone, not making them gone.

Reconciling "mass simultaneous" without a server disconnect: the MAXHUBs drop their own sockets (staggered, but correlated in time because they finish the initial content load around the same moment — e.g. after a content push or a shared power event). The heartbeat checker then flips a batch of them to offline on a single 10s tick (plus the 5s deferral), so the CMS dashboard shows a synchronized offline wave that never corresponds to a synchronized server disconnect. That reporting artifact is the "mass simultaneous" signal — and it behaves the same on beta5 and 1.9.2.


Phase 2 — FIX or CARRY (1.9.2 vs 1.9.2-beta5)

Path beta5 1.9.2 (main) Effect on #148
Android player socket/reconnect code byte-identical (only versionCode bumped) Neither fixes nor changes it. The client bug is untouched.
Heartbeat checker live-socket guard + marks offline, no close same No change to the offline-reporting artifact.
pruneStatusLog whole-table ROW_NUMBER sort (4048s freeze) chunkedDelete (non-blocking) Fixes the freeze/death-spiral — a different failure mode, not seen in #148 (no freeze/restart in the logs).
Flap limiter + 30-min quarantine absent present (lib/flap-limiter.js, 20/5min → quarantine) CARRY / WORSEN: a flapping MAXHUB is now throttled and quarantined — it will "stop retrying / go offline" sooner than on beta5.

Verdict: For the actual #148 mechanism (client-side drop), 1.9.2 is inert where it matters (identical client code, no server disconnect) and counterproductive on the secondary dynamic (the new flap-limiter quarantines the flapping client harder).

Reconciling the one success row (Fire TV, 1.9.2 staging, days)

The clean isolation is in #148 itself: same server, same APK, same network → Fire TV survives, MAXHUB drops. The variable is the device, not the server. The task's other row (beta7 APK, beta5-prod vs 1.9.2-staging) confounds device and server and therefore can't isolate anything; the staging row also happens to be a single idle device (no fleet, tiny device_status_log, no flapping to throttle) — which removes every secondary aggravator too. Net: the survival tracks the MAXHUB-vs-FireTV device difference, with "staging = one idle device" masking the flap-limiter aggravation on top.

Most likely client root cause (to be confirmed with MAXHUB logcat, the "not yet captured" item in #147): MAXHUB firmware/WebView power- or memory-management throttling or killing the app's socket/JS timers after the heavy initial content load, so the Engine.IO ping/pong lapses and the client closes — then its rapid reconnects trip the server throttle (and, on 1.9.2, the flap quarantine), ending in "offline, stops retrying." Fire TV's resource/power handling doesn't do this.

What would falsify this conclusion

  • MAXHUB logcat showing the server sent a close/device:auth-error/throttle before the client closed (would move blame server-ward).
  • The Fire TV Stick also dropping under real fleet load on the same server (would reopen a load/server-side theory). Capturing the MAXHUB logcat at the moment of disconnect is the single highest-value missing evidence.

Proposed fix (do NOT implement in this task)

  1. Client (the real fix): in the MAXHUB/Android player, harden the socket lifecycle after initial sync — a foreground service + partial wakelock to keep the socket alive, an app-level heartbeat/keepalive independent of the WebView timer, and a reconnect policy that backs off but never permanently stops retrying. Confirm against MAXHUB logcat first.
  2. Server mitigation (reduces the symptom, not the cause): since the flap limiter now punishes a flapping MAXHUB harder, consider making it more forgiving for identified/paired devices (raise CONNECT_RATE_MAX, or exempt a known device_id from quarantine) so a client with a flaky socket keeps getting let back in instead of being quarantined for 30 min. This makes 1.9.2 no worse than beta5 for this case while the client fix is developed.
  3. Do not tell Bold that upgrading the server to 1.9.2 resolves #148/#147.